BAL Ratings for a Portable Home: Bushfire Attack Levels, What Each One Requires and What It Adds to the Cost
If your block is on bushfire-prone land, and most rural, hinterland and bush-fringe blocks in Australia are, a Bushfire Attack Level (BAL) assessment is the first thing to get, because it decides how the home must be specified, whether it can be approved as complying development, and how much it costs. This guide explains how a BAL is assessed, what each level requires under the Australian Standard AS 3959, how the rating interacts with the approval pathway in each state, and what each level adds to the price of a portable home.
Portable Tiny Homes supplies BAL-rated specifications for its steel-framed homes on request. See the model range and the off-grid hub guide.
Is my land bushfire-prone?
Each state maps bushfire-prone land: the NSW Planning Portal and each council’s Bushfire Prone Land Map in NSW, the State Planning Policy bushfire hazard mapping in Queensland, the Map of Bush Fire Prone Areas in WA, the Hazards (Bushfire) overlay in SA’s Planning and Design Code, and the Bushfire Management Overlay in Victoria. If any part of the lot is mapped, a BAL assessment is needed before a dwelling can be approved. The maps are conservative: many suburban blocks on the bush fringe are included.
How a BAL is assessed
An accredited bushfire consultant (or, for simple sites, the certifier using the AS 3959 simplified method) looks at four things: the Fire Danger Index for the region, the type of vegetation within 100 m (forest, woodland, scrub, grassland), the slope under that vegetation, and the distance from the vegetation to the building. The result is one of six levels, and the cost of the assessment is $500 to $1,500. Because distance is the biggest lever, moving a portable home 10 m further from the tree line can drop a rating by a full level, which is a decision worth making before the site plan is drawn.
What each level requires
| BAL | Exposure | Main building work requirements (AS 3959) | Typical cost premium on a portable home |
|---|---|---|---|
| BAL-LOW | Insufficient risk to warrant measures | None | Nil |
| BAL-12.5 | Ember attack | Ember-proof gaps (≤2 mm mesh on vents and weepholes), non-combustible or bushfire-resisting subfloor enclosure or elevated clearance, toughened glass in windows within 400 mm of the deck, metal flyscreens | $1,500–$4,000 |
| BAL-19 | Ember attack and radiant heat to 19 kW/m² | As BAL-12.5 plus toughened glass 5 mm to all windows, metal screens, bushfire-resisting or non-combustible decking and external doors, sealed roof and wall junctions | $3,000–$7,000 |
| BAL-29 | Radiant heat to 29 kW/m², some flame contact | As BAL-19 plus non-combustible or bushfire-resisting cladding, 6 mm toughened glass or bushfire shutters, non-combustible subfloor and deck framing, sarking behind cladding | $6,000–$12,000 |
| BAL-40 | Radiant heat to 40 kW/m², increased flame contact | Non-combustible cladding and framing throughout, bushfire shutters or fire-rated glazing, non-combustible decks, tested door and window systems, enclosed subfloor | $15,000–$30,000; not all models suitable |
| BAL-FZ (Flame Zone) | Direct flame contact | Fire-rated wall, roof and floor systems (FRL 30/30/30 or higher), tested bushfire shutters, non-combustible everything; usually requires a performance solution | Often impractical for a portable home; consider relocating the site |
A steel-framed home with steel cladding starts with an advantage: the frame and skin are non-combustible, so the BAL-12.5 to BAL-29 upgrades are mostly glazing, screens, sealing and subfloor enclosure rather than structural changes.
How the BAL affects approval
In NSW, a secondary dwelling on bushfire-prone land can still be complying development up to BAL-29, provided it meets the Housing Code’s bushfire provisions and the certifier is satisfied with the BAL certificate; BAL-40 and Flame Zone require a DA and Rural Fire Service concurrence. In Queensland, the bushfire hazard overlay usually makes the proposal code-assessable rather than accepted development unless the design meets the overlay code. In WA, BAL-29 and below proceed to the building permit with the BAL certificate; BAL-40 and FZ need development approval. In SA, the Hazards (Bushfire) overlay sets performance outcomes assessed with the planning consent, and a CFS referral applies at higher levels. Victoria’s Bushfire Management Overlay requires a planning permit with a bushfire management statement. Our state-by-state approval guide covers each pathway.
Beyond the building: asset protection zones and water
The building standard is only half the requirement. Most states also require an asset protection zone or defendable space of managed vegetation around the dwelling (10 m to 50 m depending on the BAL), access for fire appliances, and in unconnected areas a dedicated bushfire water supply of 10,000 to 22,000 litres with a fire-brigade fitting, separate from domestic use. Our water supply guide covers the tank requirement.
Reducing your BAL before you build
- Move the home. Every extra metre from the vegetation helps; crossing a threshold (for example 20 m from forest on flat ground) can drop BAL-29 to BAL-19.
- Manage vegetation. Clearing within the allowable asset protection zone can change the assessed vegetation class.
- Use the slope. Fire runs uphill; a site above the vegetation is rated lower than one below it.
- Enclose the subfloor. A portable home on piers should have a non-combustible skirt or clearance; embers under a floor are the most common ignition path.
Approval note: the pathways described here are general information, not planning advice. Whether a particular site qualifies for any pathway is assessed by an independent building certifier and the relevant council, and approval is never guaranteed. Portable Tiny Homes works with independent certifiers and can connect you with one who assesses your site.
Frequently asked questions
Do I need a BAL assessment for a granny flat?
Yes, if any part of the lot is mapped as bushfire-prone. The certifier or council will not approve a dwelling without one.
Can a portable home be specified to BAL-29?
Yes. It is a routine specification for our steel-framed homes.
What about BAL-40?
Possible with a specific package, but expensive; we recommend a bushfire consultant first to see whether relocating the site lowers the rating.
How much does a BAL assessment cost?
$500 to $1,500 from an accredited consultant. Request a quote and tell us your BAL, or that you need one, and we will specify accordingly.